Verification Gap Ledger

All programs

Real Time Energy Management

NYSERDA. Active.

Required verification

4of 4

Independent verification

What proof of results the program's rules require.

  1. Independent evaluation using IPMVP Option C whole-building billing analysis for 39 of 42 sampled sites. Gross realization rates: electric 20 percent, fossil 42 percent, combined 24 percent; evaluated savings about 3 percent of baseline use. Government facilities were 17 of 293 projects and K-12 schools 14.

    DNV for NYSERDA, Real Time Energy Management Impact Evaluation Final Report (Oct. 2021)methods; results. Read 2026-10-10. Supports code 4. Confidence: high.

Public results

1of 4

Aggregate only

What results anyone can see, not counting award announcements.

  1. Evaluated results public at program level; no public project-level outcome data located.

    DNV for NYSERDA, Real Time Energy Management Impact Evaluation Final Report (Oct. 2021)whole report. Read 2026-10-10. Supports code 1. Confidence: medium.

Attributability

2of 3

Measured before and after

Whether an outside party could link outcomes to the funding.

  1. Weather-normalized pre and post billing analysis; no comparison group; net-to-gross not addressed.